dynamic calibration造句
例句與造句
- Dynamic calibration of pressure transducers , guide for
壓力傳感器的動態(tài)校準(zhǔn)指南 - Dynamic calibration of sensitivity of shock wave pressure sensor
沖擊波壓力傳感器靈敏度的動態(tài)校準(zhǔn) - Verification regulation of dynamic calibration of pressure transducer
壓力傳感器動態(tài)校準(zhǔn)試行檢定規(guī)程 - Research on the dynamic calibration of pvdf gauges loaded with lower stresses
壓電計在低應(yīng)力下的動態(tài)標(biāo)定 - Analysis of the transition time of step - function signals in the dynamic calibration of systems
系統(tǒng)動態(tài)校準(zhǔn)中輸入階躍信號過渡時間參數(shù)分析 - It's difficult to find dynamic calibration in a sentence. 用dynamic calibration造句挺難的
- Test analysis of the laser ' s response time in the transient dynamic calibration system of high - temperature transducer
高溫傳感器動態(tài)校準(zhǔn)系統(tǒng)中激光器響應(yīng)時間的測試分析 - To make the quasi - dynamic calibration system perfect , much work has been done in this dissertation . the main work consists of the following parts
本文基于進一步完善準(zhǔn)動態(tài)校準(zhǔn)技術(shù),為建立完善的塑性測壓器材的準(zhǔn)動態(tài)校準(zhǔn)體制的考慮,進行了大量的工作。 - Otherwise , some problems of the dynamic calibration of multi - dimension force / torque sensors are studied , and the author of this thesis also gives out his own point of view
另外,本文還分析了多維力/力矩傳感器的動態(tài)標(biāo)定實驗中的若干問題,提出了自己的看法。 - Constant amplitude force calibration - calibration of the calibration device instrumentation to be used for the dynamic calibration of non - resonant uniaxial dynamic testing systems - method
等幅力校準(zhǔn).非共振單軸向動態(tài)檢驗系統(tǒng)的動態(tài)校準(zhǔn)用校準(zhǔn)裝置儀器的校準(zhǔn).方法 - Several main detecting instruments which are used in the detecting work are introduced , such as hp5528a dynamic calibration , high - precision inductance scale micrometer and the cubical glass which has been demarcated
介紹了hp5528a雙頻激光干涉儀、高精度電感測微儀、標(biāo)準(zhǔn)平晶等檢測工作中使用的主要檢測儀器。 - The static - dynamic error can be decreased effectively by the quasi - dynamic calibration which is the direction of improving calibration system of plastic pressure - measuring elements . despite the development of more than twenty years , there are still many problems to be further studied
準(zhǔn)動態(tài)校準(zhǔn)技術(shù)可有效地減小靜動差,是塑性測壓器件校準(zhǔn)體制的改革方向,雖經(jīng)二十多年的發(fā)展,但還存在許多有待進一步研究的問題。 - The principle and the mechanical structure of the air - gap inductance - type transducer are analyzed in this article , and the static parameters are calibrated . dynamic calibration is applied to air - gap inductance - type transducer which is not good in dynamic capability , to obtain the dynamic parameters of the transducer and its measuring circuit . based on the result of the dynamic calibration , the transducer and its serving circuit are modeled so that the method of how to improve the dynamic performance can be found
本文對現(xiàn)有氣隙式電感傳感器在原理和機械結(jié)構(gòu)上作了深入的分析,對其參數(shù)進行了靜態(tài)標(biāo)定;并且針對常規(guī)電感傳感器動態(tài)響應(yīng)低,不宜用于快速動態(tài)測量的缺點,引入測試系統(tǒng)動力學(xué)的思想,設(shè)計了一套動態(tài)校準(zhǔn)系統(tǒng),對現(xiàn)有傳感器進行多次動態(tài)校準(zhǔn),根據(jù)動態(tài)校準(zhǔn)的實驗結(jié)果對現(xiàn)有傳感器建立數(shù)學(xué)模型,得到現(xiàn)有傳感器的動態(tài)特性;在此基礎(chǔ)上,根據(jù)磨床工件在線檢測的要求,設(shè)計一個硬件補償系統(tǒng)來提高整個測試系統(tǒng)的動態(tài)特性。 - 5 . the methods of temperature - correcting on copper cylinders and copper spheres are discussed . the method of unitive temperature - correcting on plastic pressue - measuring elements is put forward for the first time . large quantities of quasi - dynamic calibration tests in different temperatures are carried out on the dropper - hammer hydraulic dynamic pressure calibration device and the unitive temperature - correcting formula which accords with the traditional correcting method is got
在落錘液壓動標(biāo)裝置上組織了多批次的銅柱、銅球高低溫準(zhǔn)動態(tài)校準(zhǔn)試驗,探討了建立溫度誤差統(tǒng)一修正公式的可行性,建立了測壓銅球,測壓銅柱符合我國傳統(tǒng)修正方法的溫度統(tǒng)一誤差修正公式。 - 6 . since the monitor precision of quasi - dynamic calibration system is very important , the model of the four channel electric pressure - measuring system in frequency domain is built up . the cause of variance is analyzed . the error function of the system is defined and the formula of correcting the system error is derived
6由于落錘液壓動標(biāo)裝置校準(zhǔn)系統(tǒng)的校準(zhǔn)壓力監(jiān)測精度極為重要,本文對四路電測壓力系統(tǒng)進行頻域建模,分析了產(chǎn)生不一致的原因,定義了系統(tǒng)的誤差函數(shù)及推導(dǎo)了統(tǒng)一誤差模型的修正公式。 - 3 . a series of quasi - dynamic calibration tests by varying the pressure pulse width for the < t > 3 . 5 x 8 . 75mm pillar copper cylinders and o 4 . 763mm copper spheres are done on the dropper - hammer hydraulic dynamic pressure calibration device . by means of data analysis , the regulations of pulse width ' s effect on the two types of plastic pressure - measuring elements are obtained
3利用落錘液壓動標(biāo)裝置組織了3 . 5 8 . 75mm柱形銅柱、 4 . 763mm銅球的變脈寬準(zhǔn)動態(tài)校準(zhǔn)試驗,通過試驗數(shù)據(jù)處理,獲得了兩種型號塑性測壓器件的脈寬影響規(guī)律。